Search results

Jump to navigation Jump to search
  • 6:00 am, Tuesday, 05/26/20</center> 6:00 am, Monday, 07/06/20</center>
    5 KB (579 words) - 12:33, 14 March 2022
  • ...nforced or nonreinforced concrete. [[601 - PCC Pavement Mixtures|Division 6]] of this manual should be referenced for concrete construction. Thickness <center>6 inches (150 mm)</center>
    5 KB (706 words) - 11:49, 19 January 2022
  • ...HMA Mixtures|Division 5, HMA]] and [[601 - PCC Pavement Mixtures|Division 6, Concrete]] for general materials requirements. Review the plans and [http ...foot (3 m) straightedge. Variation of more than 1/4 inch in 10 feet (6 mm in 3 m) must be remedied.
    4 KB (545 words) - 12:41, 19 January 2022
  • ...6 inches (150 mm) should be done in stages. The initial stage is crushing 6 inches (150 mm) of HMA pavement. Subsequent stages include windrowing the [[Category:Division 3]]
    4 KB (552 words) - 16:44, 12 January 2022
  • The Construction Field Services (CFS) Division has revised the Hot Mix Asphalt (HMA) Production Manual. A brief descripti ...7000g of mixture at optimum”; plus some rearranging of information. (Page 6)
    4 KB (560 words) - 15:14, 19 June 2017
  • Removal of trees and stumps less than 6 inches (200 mm) in diameter, although not pay items, should still be measur [[Category:Division 2]]
    2 KB (326 words) - 10:07, 13 September 2023
  • ...the bottom of slope paving subbase will be placed in layers not more than 6 inches (150 mm) in depth, and compacted to not less than 95 percent of the Backfill for miscellaneous structures (sound earth) will be placed in 6 inch (150 mm) layers and compacted to not less than 95 percent of the maxim
    7 KB (1,044 words) - 10:08, 13 September 2023
  • ...is finished with a wood float and all edges are finished with a 1/4 inch (6 mm) radius. Curing compound is applied at a rate of 1 gallon per 25 square ...crete - least dimension must be 8 inches (1200 mm). Plain precast must be 6 inches (150 mm) thick and 15 square feet (1.5&nbsp;m2) surface area.
    4 KB (644 words) - 17:17, 19 September 2023
  • <center>6</center> [[Category: Division 8]]
    3 KB (428 words) - 12:44, 19 January 2022
  • ...gh the Construction Operations Engineer in the Construction Field Services Division. The VEDT membership will consist of the following individuals (or their de ::e. Administrator of the Development Services Division (if a local agency project)
    9 KB (1,297 words) - 14:57, 11 October 2022
  • * Depth - Taken after final trimming to the nearest 1/4 inch (6 mm), at a minimum of 400 linear feet (120 m) of traffic lane width or two l ...the scale weight of the aggregate unless the moisture content is more than 6 percent. Moisture tests will be made at the start of weighing operations a
    6 KB (873 words) - 14:24, 16 February 2022
  • ...rubblizing making sure there is not excessive oversize material [less than 6 inches (150 mm) is the greatest dimension]. The oversize material will hav [[Category:Division 3]]
    4 KB (536 words) - 14:18, 16 February 2022
  • ...Precast concrete footings must be supported by placing them on a compacted 6 inch (150 mm) subbase of Granular Material Class II. ...r Case 2)''' applies when the elevation of the cover is changed up or down 6 inches (150 mm) or less. The cover should be adjusted to the required elev
    7 KB (999 words) - 17:47, 12 January 2022
  • ...allotted contract time. The Contractor claims that part of this is due to 6 days of bad weather that the Engineer has documented. The other 24 days ar :::(6.0 - 4.5) X 2.0 = 3.0 days
    9 KB (1,338 words) - 10:01, 27 July 2022
  • <center><span STYLE="font: 15pt arial;">''Construction Field Services Division''</span></center> !Updated!! Division !! Section !! Summary !! What Changed
    67 KB (8,623 words) - 17:18, 11 April 2024
  • 0 – 6 6.5
    12 KB (1,593 words) - 13:11, 26 July 2022
  • <center><span STYLE="font: 15pt arial;">'''Construction Field Services Division '''</span></center> !Updated!! Division !! Section !! Summary !! What Changed
    28 KB (3,726 words) - 16:02, 8 March 2023
  • !Updated!! Division !! Section !! Summary !! What Changed |<center>6/9/2020</center>||<center>1 Supplemental</center>||<center>[[Interim_File_Re
    16 KB (2,430 words) - 15:46, 6 May 2021
  • Face forms are supported from the back form by use of division plates. See '''''Figure 802-3'''''. In addition to supporting the face fo [[File:Figure 802-3.JPG|center|thumb|600px|Figure 802-3 - Curb and Gutter Division Plates]]
    12 KB (1,916 words) - 11:49, 19 January 2022
  • ...or Construction defines marketable timber as having at least a diameter of 6 inches (150 mm) at a point 4-1/2 feet (1.4 m) above ground. On easement RO Type I - Stumps will be cut off at an elevation not more than 6 inches (150 mm) above the existing ground, and application of a growth prev
    8 KB (1,133 words) - 12:01, 28 March 2023

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)