Difference between revisions of "Chapter 2 - Data Requirements"

From MediaWiki
Jump to navigation Jump to search
(→‎2.1 Level of Detail Requirements: cleaned up foot/feet labeling issues from the server changeover)
 
(25 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 
{{Navbox DSR|Chapter_1_-_ProjectWise_Pre-Bid_Processes|Chapter_3_-_Standard_Naming_Conventions}}
 
{{Navbox DSR|Chapter_1_-_ProjectWise_Pre-Bid_Processes|Chapter_3_-_Standard_Naming_Conventions}}
  
==[[#2.1 Level of Detail Requirements|2.1 Level of Detail Requirements]]==
+
The Development Guide has moved to a Sharepoint site. [https://stateofmichigan.sharepoint.com/sites/MDOT-SPC-DevelopmentGuide New Development Guide]
  
The Reference Information Documents (RID) process will require the inclusion of proposed 3D models for all projects as a general rule.  Please refer to the [//{{SERVERNAME}}/images_design/f/f6/Project_Data_Requirements_Table.pdf Project Data Requirements Table.pdf] document to determine the categories that are required for each project type (Project Description).  The table is intended to capture the majority of the projects listed under each project description.  At the discretion of the MDOT Project Manager some of the categories or RID files may be excluded based on the project parameters.  For exceptions to all RID categories MDOT Project Managers can designated the RID category or File as 'N/A' on the [https://mdotjboss.state.mi.us/SpecProv/getDocumentById.htm?docGuid=71536ffa-6a51-4e45-b38b-da310526378b&fileName=%22 Joint RID Review Checklist and Index.xlsm] with justification provided in the Preliminary Comments column.  [mailto:MDOT-RIDSupport@michigan.gov MDOT RID Support] will then review the exceptions with the Preliminary Submittal.
+
If you haven't visited the new site yet, click the link, then click Request Access. You will be added to the Sharepoint Visitors group, and will receive an email with a link to the Development Guide. If you still have access issues, contact MDOT-EngineeringSupportTraining@michigan.gov
 
 
To help clarify the intent of when a 3D Model is required the following project types are generally excluded from this requirement:
 
* Log projects
 
* Standalone bridge projects
 
* Mill and fill projects
 
* Pavement patching and repair projects
 
* Crush and shape projects
 
* Projects without survey
 
 
Unless:
 
* There is wedging, widening, or earthwork for more than 1,000 feet
 
* The road elevation changes more than 3 feet
 
* The cross slope changes for more than 1,000 feet
 
* The superelevation or transition changes
 
* The improvements re-grade more than a total of 1,000 feet of ditch
 
* The improvements impact ROW
 
* The horizontal or vertical alignments change
 
 
The above lists are intended to be a starting point to help clarify the 3D Model requirements, and to convey the thought processes used to determine 3D Model requirements.  We encourage design teams to provide input as they work through unique and challenging situations.
 
[[File:Project Data Requirements Table.png|600px|thumbnail|center|Figure 2.1.1:  Project Data Requirements Table]]
 
 
 
{{top}}
 
 
 
==[[#2.2 Software Requirements|2.2 Software Requirements]]==
 
===[[#2.2.1 MDOT Workspace|2.2.1 MDOT Workspace]]===
 
 
 
For consistency and uniformity MDOT provides the following two CADD workspaces for free download.
 
<br />
 
<br />
 
 
 
'''MDOT_02 Workspace'''
 
 
 
:*This workspace requires Power GEOPAK SS4 or MicroStation SS4 + GEOPAK Civil Engineering Suite SS4.
 
:*The workspace no longer supports SS3.
 
:*The MDOT_02 Workspace is available for download by consultants at the following link:
 
:::http://mdotjboss.state.mi.us/SpecProv/trainingmaterials.htm
 
:::Go to All - Software and Workspaces.
 
:::Consultant installation instructions are located in the “M:\MDOT_02 Workspace\1_Install” folder.
 
:*The MDOT_02 Workspace install procedure supports the following applications:
 
:::a) Power GEOPAK SS4
 
:::b) MicroStation SS4 + GEOPAK Civil Engineering Suite SS4
 
:::c) Stand-alone MicroStation SS4
 
 
 
 
 
'''MDOT CONNECT Configuration'''
 
 
 
:*This configuration is required for all new projects started after October 1, 2020.
 
:*The MDOT CONNECT configuration is available for download by consultants at the following link:
 
:::http://mdotjboss.state.mi.us/SpecProv/trainingmaterials.htm
 
:::Go to All - Software and Workspaces.
 
:::Consultant installation instructions are located in the “MDOT Connect Configuration Install\” folder.
 
:*The MDOT CONNECT Workspace install procedure supports the following applications:
 
:::a) OpenRoads Designer CONNECT Edition
 
:::b) OpenBridge Modeler CONNECT Edition
 
:::c) Microstation CONNECT Edition
 
 
 
:*If you are in the early stages of a project started using the MDOT_02 Workspace and need assistance with upgrading of survey & design data for use with the MDOT CONNECT Configuration, please contact MDOT-CADDSupport@michigan.gov.
 
 
 
{{top}}
 
 
 
===[[#2.2.2 MDOT Road Design Software Requirements|2.2.2 MDOT Road Design Software Requirements]]===
 
 
 
In order to provide consistent, uniform deliverables MDOT designers must utilize the current MDOT accepted version of Bentley products.  Please note that any of the software applications below are compatible with the applicable workspace:
 
 
 
 
 
{| class="wikitable"
 
|-
 
! MDOT_02 Workspace !! MDOT CONNECT Workspace
 
|-
 
| Civil Suite SS4 Update 3 - (081109903en.exe) || OpenRoads Designer 2020 Release 2 (ord10080133en.exe)
 
|-
 
| MicroStation_SS4 - (081109832en.exe) || Microstation CONNECT Edition Update 13 (ms10130101en_updt13.exe)
 
|-
 
| Power GEOPAK SS4 Update 3 - (081109904en.exe) ||
 
|-
 
| Survey Only - Power GEOPAK SS4 Update 3 - (081109885PB.exe) ||
 
|-
 
| Civil Suite SS10      (gkste081109918en.exe) ||
 
|-
 
| MicroStation SS10    (ms081109912en.exe) ||
 
|-
 
| Power GEOPAK SS10    (pgk081109918en.exe) ||
 
|}
 
 
 
 
 
This software must be used in conjunction with MDOT’s current Workspace or Configuration.  Refer to [[Chapter_2_-_Data_Requirements#2.2.1 MDOT_Workspace|Section 2.2.1]] MDOT Workspace.
 
{{top}}
 
 
 
===[[#2.2.3 MDOT Bridge Design Software Requirements|2.2.3 MDOT Bridge Design Software Requirements]]===
 
 
 
In order to provide consistent, uniform deliverables MDOT designers must utilize the current MDOT accepted version of Bentley products.
 
 
 
{| class="wikitable"
 
|-
 
! MDOT_02 Workspace !! MDOT CONNECT Workspace
 
|-
 
| See section 2.2.2 || OpenRoads Designer 2020 Release 2 (ord10080133en.exe)
 
|-
 
|                  || Microstation CONNECT Edition Update 13 (ms10130101en_updt13.exe)
 
|-
 
|                  || OpenBridge Modeler Update 8.1 (obm10080245en.exe)
 
|-
 
|                  || OpenBridge Designer Update 8.1 (brges10080130en.exe)
 
|-
 
|                  || ProStructures Update 4 (ppst10040047en_updt4.exe)
 
|}
 
 
 
 
 
{{top}}
 
 
 
===[[#2.2.4 MDOT Drainage and Utility Design Software Requirements|2.2.4 MDOT Drainage and Utility Design Software Requirements]]===
 
<span style="color: red"> -Reserved- </span>
 
 
 
{{top}}
 
 
 
==[[#2.3 Digital File Formats|2.3 Digital File Formats]]==
 
 
 
Electronic Data is to be delivered in the following digital file formats:
 
 
 
{| class="wikitable"
 
|-
 
! File Type!! MDOT Delivered Format
 
|-
 
| CAD Graphics (2D & 3D)|| .dgn (MicroStation / Power GEOPAK design file)
 
|-
 
| Survey Control Coordinate Files|| ASCII .txt
 
|-
 
| Alignments (Horizontal and Vertical)|| .xml
 
|-
 
| Existing & Proposed Surface Data|| .xml
 
|-
 
| Cross Section Data|| .dgn and .pdf
 
|-
 
| Reports|| .pdf
 
|-
 
| Project PDF submittals ('''Only for designated Project PDF jobs''')|| .pdf
 
|-
 
| Removal and Construction Quantity files ('''Only for designated Project PDF jobs''')|| .kmz
 
|-
 
| Photographs|| .jpeg
 
|}
 
'''Table 2.3.1'''
 
{{top}}
 
 
 
==[[#2.4 Guidelines for Plan Preparation|2.4 Guidelines for Plan Preparation]]==
 
{{move|Content Type=Section|New Location=[[Chapter 7 - Plan and Proposal Preparation]]}}
 
{{top}}
 
 
 
[[CATEGORY: RID]]
 

Latest revision as of 12:58, 24 April 2024

The Development Guide has moved to a Sharepoint site. New Development Guide

If you haven't visited the new site yet, click the link, then click Request Access. You will be added to the Sharepoint Visitors group, and will receive an email with a link to the Development Guide. If you still have access issues, contact MDOT-EngineeringSupportTraining@michigan.gov